Home  |  Contact Us  |  Tell a Friend  |  Site Map
 
  Tech Sheet FW INT 02
   
 

Tech Data Sheet FW-INT-02

Nilfire Icon Fire Resistant Glazing Systems
One hour to four hour - -/60/- to -/240/- Fire Resistance Level

"Fire Windows - Integrity Only"


 

 

DESCRIPTION                                                                                 

Steel framed fire rated window providing one hour of integrity only protection with 5mm Firelite ceramic glass, This system an appropriate solution for applications requiring certified fire resistance, with a requirement for clear glass.

APPLICATIONS

Boundary walls, houses, factories, Car parks, and wherever there is a need for integrity only fire protection.

FEATURES
    • Fully certified to Australian Standards AS1530.4
    • -/60/- to -240/- FRL
    • Internal and external applications
    • 5mm Firelite ceramic glass
    • Forster® Presto non insulated framing system
    • Standard finish is powder coat with zinc enriched undercoat Selected standard powder coat colour
    • Single panes up to 2375 x 1200 per pane
    • Multi panes up to 2375 x 1200 per pane 
    • Multi pane systems up to 3m high, no limitation on span
    • For use in 1hr timber and steel stud walls, all fire rated masonry walls, gypsum block walls, aerated concrete  blocks and wall panels. 'Refer to Nilfire if your wall  type is not listed'.
HOW TO SPECIFY

Eg, “Window to be fully tested and certified NILFIRE Fire Window, 
....FRL (insert rating-60/- to -/240/-), incorporating Forster
non-insulated steel frame and 5mm ceramic Firelite glass, with
ceramic tape gaskets and silicone weather seal*.”

OPTIONAL EXTRAS

Stainless Steel frames
Tinted and Translucent  safety films
Arched windows
Can be integrated with steel framed glass fire doors
(Contact Nilfire for more information)


WALL ABUTMENTS AND BUILDING IN DETAILS

All windows must be tightly sealed to surrounding fire rated wall using  fire rated acrylic sealant or . For external applications, an additional layer of weather resistant silicone must be applied to the exposed acrylic fire rated sealant to create a water resistant barrier. All required flashings are by builder or other parties. Most fixings are approved for most wall types.

Fixing type 1

M6 Dynabolt into masonry wall or 12G screws into fire rated Gyprock wall at max 600mm centers. Can only be used for  site glazed applications. Fixings to 3 sides minimum.

Fixing type 2

 

M6 Flat head Dynabolt into masonry wall or 12G screws into fire rated Gyprock wall at max 600mm centers.  Can only be used for site glazed applications. Fixings to 3 sides  minimum.

 
 
Fixing type 3

M6 Dynabolt into masonry wall or 12G screws into fire rated Gyprock wall through 80 x 50 x 2.5 welded steel plate at max600mm centers. Can be used for factory glazed or site glazed applications. Fixings to 3 sides minimum.
  

Fixing type4

 


M6 Dynabolt into masonry wall or 12G screws into fire rated Gyprock wall through 80 x 50 x 2.5 screw attached steel plate (2qty 10G screws per plate) at max 600mm centers. Can be used for factory glazed or site glazed applications. Fixings to 3 sides minimum

 

  Click to contact Nilfire Online, or 02 9986 0844 - Download Brochure of this Page

 
 
 