Tech Data Sheet FW-INT-02
Nilfire Icon Fire Resistant Glazing Systems One hour to four hour - -/60/- to -/240/- Fire Resistance Level "Fire Windows - Integrity Only"

DESCRIPTION Steel framed fire rated window providing one hour of integrity only protection with 5mm Firelite ceramic glass, This system an appropriate solution for applications requiring certified fire resistance, with a requirement for clear glass. APPLICATIONSBoundary walls, houses, factories, Car parks, and wherever there is a need for integrity only fire protection. FEATURES- Fully certified to Australian Standards AS1530.4
- -/60/- to -240/- FRL
- Internal and external applications
- 5mm Firelite ceramic glass
- Forster® Presto non insulated framing system
- Standard finish is powder coat with zinc enriched undercoat Selected standard powder coat colour
- Single panes up to 2375 x 1200 per pane
- Multi panes up to 2375 x 1200 per pane
- Multi pane systems up to 3m high, no limitation on span
- For use in 1hr timber and steel stud walls, all fire rated masonry walls, gypsum block walls, aerated concrete blocks and wall panels. 'Refer to Nilfire if your wall type is not listed'.
HOW TO SPECIFYEg, “Window to be fully tested and certified NILFIRE Fire Window, ....FRL (insert rating-60/- to -/240/-), incorporating Forster non-insulated steel frame and 5mm ceramic Firelite glass, with ceramic tape gaskets and silicone weather seal*.” OPTIONAL EXTRASStainless Steel frames Tinted and Translucent safety films Arched windows Can be integrated with steel framed glass fire doors (Contact Nilfire for more information) WALL ABUTMENTS AND BUILDING IN DETAILS
All windows must be tightly sealed to surrounding fire rated wall using fire rated acrylic sealant or . For external applications, an additional layer of weather resistant silicone must be applied to the exposed acrylic fire rated sealant to create a water resistant barrier. All required flashings are by builder or other parties. Most fixings are approved for most wall types. Fixing type 1 M6 Dynabolt into masonry wall or 12G screws into fire rated Gyprock wall at max 600mm centers. Can only be used for site glazed applications. Fixings to 3 sides minimum. Fixing type 2
M6 Flat head Dynabolt into masonry wall or 12G screws into fire rated Gyprock wall at max 600mm centers. Can only be used for site glazed applications. Fixings to 3 sides minimum. 
Fixing type 3M6 Dynabolt into masonry wall or 12G screws into fire rated Gyprock wall through 80 x 50 x 2.5 welded steel plate at max600mm centers. Can be used for factory glazed or site glazed applications. Fixings to 3 sides minimum. Fixing type4
M6 Dynabolt into masonry wall or 12G screws into fire rated Gyprock wall through 80 x 50 x 2.5 screw attached steel plate (2qty 10G screws per plate) at max 600mm centers. Can be used for factory glazed or site glazed applications. Fixings to 3 sides minimum
Click to contact Nilfire Online, or 02 9986 0844 - Download Brochure of this Page |